5

O.C(Over Current) error

Indoor display

ل

Outdoor error

Outdoor display

ل

ل

Comp starting error

1.Checklist :
1) Is the IPM Shunt(A*V18***:R451,R452,R453,A*V24***:R413,R414,R415) resistance value correct? Check the resistor is opened
2) Is the condition of surrounding temperature abnormal overload?
3) Is there any problem as like the temperature sensor separation or measurement value error?
4) Is the interphase resistance of compressor normal?

2. Troubleshooting procedure

Is the O.C error occurred?

Terminate the service

NO

YES

Is the connec

Ɵon of compressor

wire is normal?

YES

Is the compressor body and

interphase resistance insulated?

NO

Exchange the Outdoor PBA

Connect the comp wire normally

YES

NO

Exchange the compressor

Is the O.C error occurred again?

Terminate the service

NO

YES

Restart a

Ōer power oī.

Is the condi

Ɵon of indoor/outdoor

temperature normal load?

Restart a

Ōer returning to the normal load

YES

NO

Is the O.C error
occurred again?

Terminate the
service

YES

NO

Is the posi

Ɵon of temperature

sensor and sensing value normal?

Correct the sensor posi

Ɵon or exchange the sensor

YES

NO