2 outdoor unit, Error display-aqx36vfuagm/cv – Sunlight Supply Samsung Programmable Thermostat for Split Systems User Manual

Page 95

Advertising
background image

12-32

Samsung Electronics

No.

Error Code

Meaning

Remarks

1

E201

Unit quantity miss matching between indoor and outdoor.

Check indoor quantity setting in outdoor (Refer to

page 17.)

2

E202

Abnormal state, no communication between Indoor and Outdoor

Main PCB

Check electrical connection and setting

3

E203

1min. Time out of communcation error(Main

Inverter)

Check electrical connection and setting

4

E221

Outdoor temp sensor error

Check Outdoor sensor Open/Short

5

E231

Cond. temp sensor error

Check Cond. sensor Open/Short

6

E251

Discharge temp sensor error

Check Discharge sensor Open/Short

7

E320

OLP Sensor Error

Check OLP sensor Open/Short

8

E403

Detection of Outdoor Freezing when Comp. Stop

Check Outdoor Cond.

9

E404

Protection of Outdoor Overload when Comp. Stop

Check Comp. when it start

10

E416

Discharge temperature of a compressor in an

outdoor unit is overheated.

11

E440

Heating operation is not available since the outdoor air tem-

perature is over 30°C.

Heating

E441

Cooling operation is not available since the outdoor air tem-

perature is lower than -5°C.

Cooling

12

E458

Outdoor unit BLDC Fan 1 or Fan 2 error

FAN1 error

E475

FAN2 error

13

E461

Comp. Starting error

14

E462

Primary Current Trip error

15

E463

Over current trip / PFC over current error

Check OLP sensor

16

E464

IPM(IGBT Module) Over Current(O.C)

17

E465

Comp. Over load error

18

E466

DC-Link voltage under/over error

Check AC Power or DC_Link voltage

19

E467

Comp. wire missing error

Check Comp. wire

20

E468

Current sensor error

Check Outdoor Inverter PBA

21

E471

Outdoor EEPROM error

Check Outdoor EEPROM date

22

E474

IPM(IGBT Module) or PFCM Temperature sensor Error

Check Outdoor Inverter PBA

23

E484

PFC Overload Error

Check Outdoor Inverter PBA

24

E500

IPM is over heated.

Check Outdoor Inverter PBA

25

E554

GAS Leak error

Check indoor and outdoor unit model

26

E556

Capacity miss match between indoor and outdoor

Check indoor and outdoor unit model

If an error occurs during the operation, it is displayed on the outdoor unit PCB LED, both MAIN PCB and INVERTER PCB.

12-2 Outdoor Unit

Error Display-AQX36VFUAGM/CV