12-

19

Current sensor error/Input current sensor error

Indoor display

ل

Outdoor error

Outdoor display

م

Current

sensor

error/Input

current

sensor error

1.Checklist :
1) Is the PFC Shunt(A*V18***:R062,R063,A*V24***:R807,R808,R809) resistance value correct? Check the resistor is opened
2) Is the IPM Shunt(A*V18***:R451,R452,R453,A*V24***:R413,R414,R415) resistance value correct? Check the resistor is opened
3) Is there no short or open around IC451(A*V18***) or IC451,IC452(A*V24***)?

2. Troubleshooting procedure

Is the PFC shunt and IPM shunt

resistance value correct?

Exchange the Outdoor PBA

Is the current sensor error

appeared again?

YES

Terminate the service

NO

NO

Exchange the Outdoor PBA

Restart a

Ōer power oī.