Idle Activation Criteria:
Idle On Below TPS [% ]:
Closed-loop idle feedback will be active when the throttle position is below this value, and
the 'Idle On Below RPM' condition is also met.
Min value = 0, Max value = 10
Idle On Below RPM [RPM]:
Closed-loop idle feedback will be active when the EngineSpeed is below this value, and
the 'Idle On Below TPS' condition is also met.
Min value = 500, Max value = 3000
Idle Feedback Min [% ]:
Minimum amount of correction allowed
Min value = -50, Max value = 0
Idle Feedback Max [% ]:
Maximum amount of correction allowed
Min value = 0, Max value = 50