AEM 30-71XX Infinity Stand-Alone Programmable Engine Mangement System Full Manual User Manual

Page 178

Advertising
background image

172

© 2014 AEM Performance Electronics

Infinity User Manual

be > Exh Pressure Min Volts. User entries that do not meet this criteria are not allowed.

Exhaust Pressure Cal Min [psig]:
This sets the minimum pressure capable, in psig, from a properly working sensor. Check the
manufacturer specifications for more information. Min value = 0, Max value = 125. Exh Pressure
Cal Max must be > Exh Pressure Cal Min. User entries that do not meet this criteria are not
allowed.

Exhaust Pressure Cal Max [psig]:
This sets the maximum pressure capable, in psig, from a properly working sensor. Check the
manufacturer specifications for more information. Min value = 0, Max value = 125. Exh Pressure
Cal Max must be > Exh Pressure Cal Min. User entries that do not meet this criteria are not
allowed.

Exhaust Pressure Sensor Installed
If a barometric pressure sensor is installed, check this box.

Exhaust Pressure Smoothing
Value used to smooth signal. Min value = 0, Max value = 98.

Exhaust Pressure Failsafe On:
When clicking, the failsafe feature is enabled. This is typically used when the sensor is
mistakenly unplugged or has failed.

Exhaust Pressure Failsafe:
The value entered here will be displayed and used for the exhaust pressure corrections when the
sensor has failed or is simply unplugged. Min value = 0, Max value = 125

Advertising