AEM 30-71XX Infinity Stand-Alone Programmable Engine Mangement System Full Manual User Manual
Page 213

Tuning Guide
207
© 2014 AEM Performance Electronics
Nitrous Trims: Advanced Setup:
Nitrous Output Delay:
Units: Time
Nitrous Trim Delay:
Units: Time
Nitrous Trim Decay Time:
Units: Time
Associated Tables:
N2O_Switch:
Units: Off = 0, On = 1
This table sets digital input condition to arm Nitrous, Set all cells to 1 if not using a digital input to
arm.
N2O_Fuel:
Units: Pressure vs Engine Speed vs Fuel % (decimal)
Range: Min value = -1.00, Max value = 1.55
This map allows a percentage of additional fuel to be added or subtracted from the base map
when the nitrous options become active. This map allows adjustment over engine speed and
manifold pressure.
N2O_Ign [deg]:
Units: Pressure vs Engine Speed vs Degrees
Range: Min value = -43.75, Max value = 20.00
This map allows ignition timing to be advanced or retarded against the base ignition map when
the nitrous control is active. This map is adjustable over engine speed and manifold pressure.