Ignition Trim IDLE PID Feature:

Although not generally needed, a closed loop ignition trim for idle is now available. The following
setup wizard settings are used to enable the feature.

When enabled, this feedback control system will use closed loop ignition timing changes to help
maintain a target idle.

Idle Feedback Disable Window Feature:

Can be used in place of the Idle On Below RPM option. This is a more adaptive way of
managing the idle target while decelerating in gear. It can prevent integral wind up and potential
stalling problems when the clutch pedal is pushed in while coasting to a stop.