364

© 2014 AEM Performance Electronics

Infinity User Manual

Infinity Pin

Hardware Ref.

Hardware Specification

Notes

C1-15

Coil 6_Out

25 mA max source current

0-5V Falling edge fire. DO NOT connect directly
to coil primary. Must use an ignitor OR CDI that
accepts a FALLING edge fire signal.

C1-16

Coil 5_Out

25 mA max source current

0-5V Falling edge fire. DO NOT connect directly
to coil primary. Must use an ignitor OR CDI that
accepts a FALLING edge fire signal.

C1-17

Crankshaft Position Sensor
VR+_In

Differential Variable Reluctance Zero
Cross Detection

See Setup Wizard page Cam/Crank for options.

C1-18

Crankshaft Position Sensor
VR-_In

See Setup Wizard page Cam/Crank for options.

C1-19

Camshaft Position Sensor 1
VR-_In

Differential Variable Reluctance Zero
Cross Detection

See Setup Wizard page Cam/Crank for options.

C1-20

Camshaft Position Sensor 1
VR+_In

See Setup Wizard page Cam/Crank for options.

C1-21

LowsideSwitch_2_Out

Lowside switch, 1.7A max, NO internal
flyback diode.

No pullup

See Setup Wizard Pages "User GPOs" for
activation criteria and "LowSide Assignment
Tables" for output assignment

C1-22

LowsideSwitch_3_Out

Lowside switch, 6A max with internal
flyback diode. Inductive load should
NOT have full time power.

No pullup

See Wizard page "LowSide Assignment Tables"
for output assignment.
MIL Activates when any of the following flags are
true: ErrorAirTemp, ErrorBaro,
ErrorCoolantTemp, ErrorEBP, ErrorFuelPressure,
UEGO_0_Diag_error, UEGO_1_Diag_error,
ErrorMAFAnalog, ErrorMAFDigital, ErrorMAP,
ErrorOilPressure, ErrorThrottle.

C1-23

AGND_1_Out

Dedicated analog ground

Analog 0-5V sensor ground

C1-24

AGND_1_Out

Dedicated analog ground

Analog 0-5V sensor ground

C1-25

Crankshaft Position Sensor
Hall_In

10K pullup to 12V. Will work with
ground or floating switches.

See Setup Wizard page Cam/Crank for options.

C1-26

Camshaft Position Sensor 1
Hall_In

10K pullup to 12V. Will work with
ground or floating switches.

See Setup Wizard page Cam/Crank for options.

C1-27

Digital_In_2

10K pullup to 12V. Will work with
ground or floating switches.

See Setup Wizard page Cam/Crank for options.

C1-28

Dig3 [Hz] / Dig3_Duty_In

10K pullup to 12V. Will work with
ground or floating switches.

Frequency input can be assigned to Wheel
Speed, TurboSpeed, Flex Fuel or other functions.
See Setup Wizard page Input Function
Assignments for mapping options.

C1-29

Dig4 [Hz] / Dig4_Duty_In

10K pullup to 12V. Will work with
ground or floating switches.

See Setup Wizard page Vehicle Speed for
calibration constant.

C1-29

RS232 Rx_In

RS232 Line Driver/Receiver

Future expansion

C1-30

Digital_In_5

10K pullup to 12V. Will work with
ground or floating switches.

See ClutchSwitch 1-axis table for setup options.
Input can be assigned to different pins. See
Setup Wizard page Input Function Assignments
for input mapping options.

C1-30

RS232 Tx_Out

RS232 Line Driver/Receiver

Future expansion

Advertising