AEM 30-71XX Infinity Stand-Alone Programmable Engine Mangement System Full Manual User Manual
Page 224
Advertising
218
© 2014 AEM Performance Electronics
Infinity User Manual
The following values were used in this example:
Shift Cut Minimum RPM = 3000 RPM
Shift Cut Minimum Throttle = 20%
Shift Cut Re-Arm Delay Time = 1000 ms
ShiftCutTime = table set to 110ms for 4th gear
Shift Cut Method = Ign Retard + Fuel Cut
Ign Retard Amount = 10 degrees
Ign Retard Ramp-Out Time = 100ms
For more information, see the
section of the wizard.
215