The following values were used in this example:

Shift Cut Minimum RPM = 3000 RPM
Shift Cut Minimum Throttle = 20%
Shift Cut Re-Arm Delay Time = 1000 ms

ShiftCutTime = table set to 110ms for 4th gear
Shift Cut Method = Ign Retard + Fuel Cut
Ign Retard Amount = 10 degrees
Ign Retard Ramp-Out Time = 100ms

For more information, see the

Shift Cut

section of the wizard.