Power supply – 2N StarGate/BlueTower v5.3 User Manual

Page 16

Advertising
background image

16

2N TELEKOMUNIKACE a.s., www.2n.cz

®

Figure: 

 with 4 UMTS Boards, Basic CPU, 2 ISDN PRI, VoIP Interfaces

2N BlueTower

®

Note

Please keep all cards in the right positions. Wrong positions will
cause malfunction of whole system!
In  the  case  of  VoIP  card  replacement  by  ISDN  PRI  (and  vice
versa) please read the instructions in Section 

.

2.4 Installation

Power Supply

The system uses an industrial power supply unit with natural cooling and an auxiliary
external  fan,  which  is  switched  on  automatically  whenever  the  power  supply
temperature  exceeds  70°C.  The  power  supply  unit  is  designed  with  a  30%  reserve
even under the maximum load. 

Power supply types

Internal 90–260V / 50 – 60 Hz (output 5V / 30A).

Caution

Make  sure  that  the  incoming  supply  is  matching  the  requested
values!
High voltage may cause a serious injury or death!

Tip

You  are  recommended  to  connect  the  gateway  to  the  UPS
system.