GSM / UMTS signal intensity (minimum recommended signal level

). You

: –80dB

can  use  the  NET  monitor  on  a  mobile  phone  (e.g.  Nokia,  Siemens)  or  the
diagnostics  screen  in  the  web  interface  for  measuring  the  GSM  /  UMTS  signal
intensity.
Unoverloadable GSM / UMTS cells to which the gateway modules are logged in;
please  keep  in  mind  that  up  to  30  calls  are  set  up  at  a  time  during  full  traffic
(according to the gateway configuration).
No strong electromagnetic radiation is allowed on the system installation site.
No strong electromagnetic reflections are allowed on the antenna installation site.
The  ISDN  PRI  connection  must  be  configured  properly  and  meet  the  ITU–T
Q.931–EDSS1 and related recommendations.
The VoIP – SIP signalling must meet the required RFCs.
Place the gateway into an environment that complies with the gateway working
conditions (an air conditioned room or installation rack).
An  appropriate  (according  to  the  power  supply  unit  used)  power  feeding  with
overvoltage protection and an on–line UPS are recommended.
An  Ethernet  connection  on  the  installation  site  is  advisable  for  comfortable
gateway administration.
All the SIM cards to be used must have the same PIN code (or deactivated PIN
code) and be activated by the GSM / UMTS provider.

Warning

The outdoor antenna cable has to be connected according to the
overvoltage protection and grounding safety rules.
High temperatures on the installation site may cause short–time
or permanent gateway errors!

Warning

Do not cover the top, bottom and rear sides of the gateway to
avoid overheating and gateway error!
Protection  against  humidity  and  extreme  temperatures:  The
appliance may never be placed close to heat sources (radiators)
or  places  exposed  to  direct  sunshine.  Also  places  with  high
humidity (such as bathrooms and cellars), places with significant
temperature  fluctuation  (next  to  doors,  windows),  dusty  places
(workshops)  and  places  exposed  to  aggressive  gases
(accumulator  rooms,  boiler  rooms)  as  well  as  places  with
intensive  vibrations  and  places  exposed  to  shocks  (compressor
rooms,  heavy  industrial  operations)  should  be  avoided.  The
system should be installed horizontally.

VoIP Connection

All the gateway types have the same features. The only difference lies in the number of
simultaneous calls through the VoIP card.