Communications options, Section 3.8, Figure 3.7: typical system – INFICON STM-100/MF Thin Film Deposition Monitor User Manual

Page 42: Deposition system installation, Section 3.9, System installation

Advertising
background image

COMMUNICATIONS OPTIONS

The STM-100 / MF will support two types of communications option boards.

Type 1 is the IEEE-488 parallel bus and type 2 is the industrial standard BITBUS.
Only one type of option card may be installed at a time. Both cards use the
COMM OPTION rear panel cut-out for external connection. Contact the factory for
details on having either option installed.

The computer identification address (device address) for either option card is

set in the same fashion. Dip switches 8 through 12 on the rear panel of the
STM-100 / MF set a binary address from 0 through 31. Switch 8 is the MSB and
switch 12 is the LSB. (See Table 2.2) The unit is factory-shipped set for address
0. See Section 5 for a more detailed explanation of the command and addressing
limitations.

Figure 3.7: Typical System.

DEPOSITION SYSTEM INSTALLATION

Figure 3.7 is a diagram of a typical evaporator installation. Referring to this

drawing and following the recommendations below should provide adequate
information for most installations. If further assistance is needed contact the
customer service and applications department at Sycon.

SECTION 3.8

Communications
Options

SECTION 3.9

System Installation

INSTALLATION

Page 3 - 8