Liquid fertilizer attachment, Liquid fertilizer attachment -8 – Kinze 3500 Lift and Rotate Planter Rev. 7/14 User Manual

Page 68

Advertising
background image

M0240-01

Model 3500

4-8

Rev. 10/11

TM

Fertilizer

LIqUID FERTILIzER ATTACHMENT

NOTICE

Placing fertilizer too close to seeds or in excessive amounts can
cause germination or seedling damage. Check with your fertilizer
dealer or manufacturer for correct amount and placement.

Liquid fertilizer option installed

NOTE: Optional low rate check valves are available
for in-line installation between liquid fertilizer
squeeze or piston pump and openers to ensure
equal distribution of product at low rates. Check
valves also eliminate anti-siphon loops.

Old style non-reparable
check valve

New style reparable
check valve

WARNING

Agricultural chemicals can cause death or serious injury to persons,
animals, and plants or seriously damage soil, equipment, or property.
Read and follow all chemical and equipment manufacturers labels
and instructions.

CAUTION

Prior to 2012 production. Overfilling tank can cause siphoning, tank
collapse, personal injury, and damage to property and equipment.
Do not overfill tank. Do not leave planter unattended when filling
tank. Close fill valve and open tank lid if siphoning occurs. Follow all
chemical manufacturers first aid, cleanup, and handling instructions.

Advertising