C13855

C13861

C13862

Parameter | Name:

C13855 | Length of ports mapped into send PDO

Data type: UNSIGNED_8

Index: 10720 = 0x29E0

Display of the total data length (in bytes) of the ports that have been mapped into the send PDO.
Display area

(min. value | unit | max. value)

0

255

Subcodes

Info

C13855/1

Length of ports mapped into send PDO

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13861 | Module state

Data type: UNSIGNED_16

Index: 10714 = 0x29DA

Display of the current module state
Selection list

(read only)

Info

0 Nonexistent

No online value available (communication module is

offline).

1 Device Self Test

The communication module is currently undergoing a

self-test.

2 Device Operational

The communication module is working perfectly.

3 Device in Standby

The communication module has not been completely

configured yet or the configuration is incorrect.

4 Minor Fault

The communication module has a fault that can be

rectified.

5 Unrecoverable Fault

The communication module is defective and must be

replaced.

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13862 | Network status

Data type: UNSIGNED_16

Index: 10713 = 0x29D9

Display of the current network status of the DeviceNet node
Selection list

(read only)

Info

0 Nonexistent

No online value available (communication module is

offline).

1 Not online

• The communication module is not supplied with

voltage via DeviceNet.

• The Duplicate MAC ID test has not been completed

yet.

2 Link OK

The communication module is working perfectly and has

established a connection to the scanner.

3 Online / Not connected

The communication module

• is working correctly;

• has performed the Duplicate MAC ID test;

• has not been connected to the scanner yet.

4 Minor Fault

The communication module has a fault that can be

rectified.

5 Critical Link Failure

The communication module cannot access the fieldbus

(e.g. Duplicate MAC ID, Bus Off, invalid baud rate etc.).

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT