12
Implemented DeviceNet objects
12.11
Examples for reading/writing with the »Class Instance Editor«
80
Lenze · E94AYCDN communication module (DeviceNet™) · Communication Manual · DMS 5.0 EN · 02/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.11.2
Reading integer codes
The maximum speed (n
max
) is to be read from code C0011.
Enter the following in the input fields of the »Class Instance Editor« (fig.
):
• Description: Get Single Attribute (read code)
• Class: 6E (access to Lenze code)
• Instance: B (hex value of the code)
• Attribute: 1 (hex value of the subcode)
• Output size format: Double (4 bytes)
• Output radix format: Decimal
• Read the decimal data that are returned:
”Data received from the device”: 4050 = 4050 [min
-1
]
[12-2] »Class Instance Editor«: Reading integer codes