Device modules

Safety module SM300

1

1.2

1.2.3

1.2-5

EDS94AYAD EN 2.2

X82.1

Labelling

Description

n. c.

This terminal strip is not assigned.

n. c.
n. c.
n. c.
n. c.
n. c.
n. c.
n. c.
n. c.

X82.2

Labelling

Description

-

GND external supply

+

24 V external supply via a safely separated power supply unit

(SELV/PELV)

n. c.

This part of the terminal strip is not assigned.

n. c.
n. c.
n. c.
AIE

Error confirmation input (Acknowledge Input Error)

CLA

Clock output for passive sensors, channel A (clock A)

CLB

Clock output for passive sensors, channel B (clock B)

X82.3

Labelling

Description

GCL

GND clock output

GI2

GND IN I2A/I2B

I2B

Sensor input 2, channel B (only for passive sensors)

I2A

Sensor input 2, channel A (only for passive sensors)

GCL

GND clock output

GI1

GND I1A/I1B

I1B

Sensor input 1, channel B (only for passive sensors)

I1A

Sensor input 1, channel A (only for passive sensors)

n. c.

This terminal is not assigned.

X82.4

Labelling

Description

GCL

GND clock output

GI4

GND I4A/I4B

I4B

Sensor input 4, channel B (only for active sensors)

I4A

Sensor input 4, channel A (only for active sensors)

n. c.

This part of the terminal strip is not assigned.

Sensor input 3 is not available.

n. c.
n. c.
n. c.
n. c.

Terminal assignment