3 safe torque off, Safe torque off, Safety engineering – Lenze E94AYAD - SM300 User Manual

Page 27

Advertising
background image

Safety engineering

Safety functions

Safe torque off

1

1.3

1.3.3

1.3-5

EDS94AYAD EN 2.2

1.3.3

Safe torque off

1.3.3.1

Description

Safe Torque Off / STO
This function corresponds to a ”Stop 0” according to EN 60204.
When this function is used, the power supply of the motor is immediately

safely interrupted. The motor cannot create a torque and thus no dangerous

movements of the drive can occur. Additional measures, e.g. mechanical

brakes are needed against movements caused by external force.
Priority function: none
Subordinated function: SS1

t

n

0

1

t1

t

0

'1'

0

SMxDIASTO

Input signal of the request of a safety function

’1’ Logic signal level ”1” / ”true”

Speed characteristic n of the motor

tx Action instant

t Time axis

1.3.3.2

Conditions

Condition for using the function:
ƒ The basic device must be equipped with a communication module

E94AYCPM (PROFIBUS-DP), SW version 0.9 and connected to the

PROFIBUS.

ƒ The basic device must receive PROFIBUS data telegrams from a master

controller.

Danger!

If the request for the safety function is cancelled, the drive will

restart automatically.
You must provide external measures which ensure that the drive

only restarts after a confirmation (EN 60204).

1.3.3.3

Settings

This function does not have any parameters to be set.

Advertising