Safety engineering

Device modules

Connection of safety sensors

1

1.2

1.2.4

1.2-9

EDS94AYAD EN 2.2

Specification

Sensor type

passive

active

Discrepancy time

30 s

Input delay

4 ms

0 ms

Input filter time for test pulses

15 ms

Repetition rate of the test

pulses

is determined by the clock

outputs CLA and CLB

> 50 ms

Error response

EC_S1

Confirmation via PROFIsafe or AIE input

Tab. 1.2-2

Specification of sensor connections

Explanations
Discrepancy time
ƒ Maximum time in which both channels of a safe input may have

non-equivalent states without the safety engineering noticing an error.

Input delay
ƒ Time between the recognition of the signal change and the effective

evaluation of an input signal. As a result, multiple and short signal

changes due to contact bounce of the components are not taken into

account.

Input filter time
ƒ Time in which the interference pulses and test pulses are not detected

by e.g. active sensors that are switched on.