Safety engineering

Safety functions

Safe PROFIsafe connection

1

1.3

1.3.5

1.3-10

EDS94AYAD EN 2.2

1.3.5.2

Response times

In order to detect the response time to a safety function the entire system

must be considered. The following is relevant:
ƒ Response time of the connected sensors.
ƒ Input delay of the safety inputs.
ƒ Internal processing time.
ƒ Monitoring time for the cyclic service in the PROFIBUS.
ƒ Monitoring time of the PROFIsafe in the safety PLC.
ƒ Processing time in the safety PLC.
ƒ Delay times due to further components.

μC

μC

S

SF

t = 0

t

1

t

2

0

1

t

ps

t

4

2

PROFIBUS

t

3

t

5

lcu12x_352

Fig. 1.3-1

Response times to the request of a safety function

Basic device

Safety module

Safety PLC

μ

C Microcontroller

S

Safety sensor technology

SF Activated safety function