Safety engineering

Device modules

Connection of safety sensors

1

1.2

1.2.4

1.2-11

EDS94AYAD EN 2.2

1.2.4.3

Connection of active sensors

The safe sensor input I4A and I4B is suitable for an active sensor.
PN-switched input signals are permissible.
The line monitoring must comply with the requirements of the category 3.

Drive-based safety does not provide for line monitoring.
These errors are detected:
ƒ Non-equivalent input signals after the discrepancy time.

GI

IB

IA

S

M

P

SSP94SM352

Fig. 1.2-5

Functional example of PN-switching sensor
S

Sensor

P

Positive path

M

Negative path