Safety engineering – Lenze E94AYAD - SM300 User Manual
Page 21
Advertising
![background image](/manuals/565813/21/background.png)
Safety engineering
Device modules
Connection of safety sensors
1
1.2
1.2.4
1.2-11
EDS94AYAD EN 2.2
1.2.4.3
Connection of active sensors
The safe sensor input I4A and I4B is suitable for an active sensor.
PN-switched input signals are permissible.
The line monitoring must comply with the requirements of the category 3.
Drive-based safety does not provide for line monitoring.
These errors are detected:
ƒ Non-equivalent input signals after the discrepancy time.
GI
IB
IA
S
M
P
SSP94SM352
Fig. 1.2-5
Functional example of PN-switching sensor
S
Sensor
P
Positive path
M
Negative path
Advertising