Safety engineering

Safety functions

Integration into the application of the controller

1

1.3

1.3.1

1.3-2

EDS94AYAD EN 2.2

Details SM_dwControl
Name

Value Description

IEC 61800-5-2

STO

0

No request

Safe Torque Off

1

Request of the function

SS1

0

No request

Safe Stop 1

1

Request of the function

SDIp

1

Safe positive direction of rotation enabled (fixed)

Safe Direction

SDIn

1

Safe negative direction of rotation enabled (fixed)

Safe Direction

-

0

Reserved for future extensions

Details SM_wState
Name

Description

IEC 61800-5-2

EC_S1

0

Normal operation

-

1

Stop category 1 error activated

EC_S0

0

Normal operation

-

1

Stop category 0 error activated

STO

0

Normal operation

Safe Torque Off

1

Pulse inhibit activated

Details SM_wIo_State
Name

Value Description

SD-I1

0

Sensor input 1 in the OFF state, at least one channel

1

Sensor input 1 in the ON state

SD-I2

0

Sensor input 2 in the OFF state, at least one channel

1

Sensor input 2 in the ON state

SD-I4

0

Sensor input 4 in the OFF state, at least one channel

1

Sensor input 4 in the ON state

AIE

0

Idle state

0  1 Error confirmed
1

Temporary status

If the communication with the basic device is interrupted, e.g. by switching

off the basic device, a fault is activated and the LED ”ME”begins blinking. The

required confirmation can be executed via AIE or PROFIsafe. Further

information can be obtained from the chapter ”Error status”.