Table 63: PositionServo Variable List

Index Name

Type Format EPM Access Description

Units

1

VAR_IDSTRING

N

R

Drive’s identification string

2

VAR_NAME

Y

R/W Drive’s symbolic name

3

VAR_SERIAL_NUMBER

R

Drive’s serial number

4

VAR_MEM_INDEX

R/W Position pointer in RAM file (0 - 32767)

5

VAR_MEM_VALUE

R/W Value to be read or written to the RAM file

6

VAR_MEM_INDEX_INCREMENT

R/W

Holds value the MEM_INDEX will increment
once the R/W operation is complete

7

VAR_VELOCITY_ACTUAL

F

N

R

Actual measured motor velocity

UU/sec

8

VAR_RSVD_2

9

VAR_DFAULT

Short Name: DFAULTS

R

Drive faults register. Holds current trip / fault
code

10

VAR_M_ID

mtr

Y

R/W* Motor ID

11

VAR_M_MODEL

mtr

Y

R/W* Motor model

12

VAR_M_VENDOR

mtr

Y

R/W* Motor vendor

13

VAR_M_ESET

mtr

Y

R/W*

Motor Feedback Resolver: ‘Positive for CW’
1 - Positive for CW
0 - negative for clockwise

14

VAR_M_HALLCODE

mtr

Y

R/W*

Hallcode index
Range: 0 - 5

15

VAR_M_HOFFSET

mtr

Y

R/W* Reserved

16

VAR_M_ZOFFSET

mtr

Y

R/W*

Resolver Offset
Range: 0 - 360

17

VAR_M_ICTRL

mtr

Y

R/W* Reserved

18

VAR_M_JM

mtr

Y

R/W*

Motor moment of inertia, Jm
Range: 0 - 0.1

Kgm2

19

VAR_M_KE

mtr

Y

R/W*

Motor voltage or back EMF constant, Ke
Range: 1 - 500

V/Krpm

20

VAR_M_KT

mtr

Y

R/W*

Motor torque or force constant, Kt
Range: 0.01 - 10

Nm/A

21

VAR_M_LS

mtr

Y

R/W*

Motor phase-to-phase inductance, Lm
Range: 0.1 - 500

mH

22

VAR_M_RS

mtr

Y

R/W*

Motor phase-to-phase resistance, Rm
Range: 0.01 - 500

[Ohm]

23

VAR_M_MAXCURRENT

mtr

Y

R/W*

Motor’s max current(RMS)
Range: 0.5 - 50

[A]mp

24

VAR_M_MAXVELOCITY

mtr

Y

R/W*

Motor’s max velocity
Range: 500 - 20,000

RPM

25

VAR_M_NPOLES

mtr

Y

R/W*

Motor’s poles number
Rnage: 2 - 200

26

VAR_M_ENCODER

mtr

Y

R/W*

Encoder resolution
Range: 256 - 65536 * 12/Npoles

PPR

27

VAR_M_TERMVOLTAGE

mtr

Y

R/W*

Nominal Motor’s terminal voltage
Range: 50 - 800

[V]olt

28

VAR_M_FEEDBACK

mtr

Y

R/W*

Feedback type
1 - Encoder
2 - Resolver

* These are all R/W variables that only become active after variable 247 is set.