Programming, 12 system status register (dstatus register) – Lenze E94P PositionServo with MVOB User Manual

Page 57

Advertising
background image

PM94H201B_13xxxxxx_EN

L

55

Programming

2.12 System Status Register (DSTATUS register)

System Status Register, (DSTATUS), is a Read Only register. Its bits indicate the various states of the PositionServo’s
subsystems. Some of the bits are available as System Flag Variables and previously summarized in Table 12.

Table 16: DSTATUS Register

Bit in register

Description

0

Set when drive enabled

1

Set if DSP subsystem at any fault

2

Set if drive has a valid program

3

Set if byte-code or system or DSP at any fault

4

Set if drive has a valid source code

5

Set if motion completed and target position is within specified limits

6

Set when scope is triggered and data collected

7

Set if motion stack is full

8

Set if motion stack is empty

9

Set if byte-code halted

10

Set if byte-code is running

11

Set if byte-code is set to run in step mode

12

Set if byte-code has reached the end of program

13

Set if current limit is reached

14

Set if byte-code at fault

15

Set if no valid motor selected

16

Set if byte-code at arithmetic fault

17

Set if byte-code at user fault

18

Set if DSP initialization completed

19

Set if registration has been triggered

20

Set if registration variable was updated from DSP after last trigger

21

Set if motion module at fault

22

Set if motion suspended

23

Set if program requested to suspend motion

24

Set if system waits completion of motion

25

Set if motion command completed and motion Queue is empty

26

Set if byte-code task requested reset

27

If set interface control is disabled. This flag is set/clear by ICONTROL ON/OFF statement.

28

Set if positive limit switch active

29

Set if negative limit switch active

30

Events disabled. All events disabled when this flag is set. After executing EVENTS ON all events
previously enabled by EVENT EventName ON statements become enabled again

PositionServo variable #83 provides Extended Status Bits, the encoding of which is listed in Table 17.

Advertising