;********************** Initialize and Set Variables ***********************

UNITS = 1

ACCEL = 75

DECEL =75

MAXV = 10

;V1 =

;V2 =
;********************** Events *********************************************

;Set Events handling here
;No events are currently defined in this program
;********************** Main Program **************************************
RESET_DRIVE:

;Place holder for Fault Handler Routine

WAIT UNTIL IN_A3:

;Make sure that the Enable input is made before continuing

ENABLE

;Enable output from drive to motor

PROGRAM_START:

;Place holder for main program loop

MOVEP 0

;Move to Pick position

OUT1 = 1

;Turn on output 1 to extend Pick arm

WAIT TIME 1000

;Delay 1 sec to extend arm

OUT2 = 1

;Turn on output 2 to Engage gripper

WAIT TIME 1000

;Delay 1 sec to Pick part

OUT1 = 0

;Turn off output 1 to Retract Pick arm

MOVED -10

;Move 10 REVs to Place position

OUT1 = 1

;Turn on output 1 to extend Pick arm

WAIT TIME 1000

;Delay 1 sec to extend arm

OUT2 = 0

;Turn off output 2 to Disengage gripper

WAIT TIME 1000

;Delay 1 sec to Place part

OUT1 = 0

;Retract Pick arm

GOTO PROGRAM_START ;Loop back and continuously execute main program loop

END
;********************** Sub-Routines ***************************************
Enter Sub-Routine code here
;********************** Fault Handler Routine ******************************
;

Enter Fault Handler code here

ON FAULT

;No Fault Handler is currently defined in this program

ENDFAULT

Saving Configuration File to PC

The “Configuration File” consists of all the parameter settings for the drive, as well as the User Program. Once you are
done setting up the drive’s parameters and have written your User Program, you can save these setting to your computer.
To save the settings, select

[Save All] from the Main toolbar. Then simply assign your configuration file a name, (e.g.

Basic Motion), and click [Save] in the dialog box. The configuration file has a “dcf.xml” extension and by default will be
saved to the “My Documents” folder.

Loading Configuration File to the Drive

There are times when it is helpful to import a a complete set-up or drive configuration to another drive. To load the
configuration file from the PC to the drive, select

[Load All] from the Main toolbar. Select the configuration file to load

and click [Open] in the dialog box. MotionView will open the selected configuration file, set all parameters within the
drive to the values contained within that file, and then extract, compile and download the saved user program. When the
process is complete the [Compilation Complete] dialog box will appear.