Reference – Lenze E94P PositionServo with MVOB User Manual

Page 117

Advertising
background image

PM94H201B_13xxxxxx_EN

L

115

Reference

Index Name

Type Format EPM Access Description

Units

234

VAR_CAN_BAUD_EPM

W

Y

R/W

CAN Bus Parameter: Baud Rate: 1 - 8
1 - 10k
2 - 20k
3 - 50k
4 - 125k
5 - 250k
6 - 500k
7 - 800k
8 - 1000k

235

VAR_CAN_ADDR_EPM

W

Y

R/W CAN Bus Parameter: Address: 1-127

236

VAR_CAN_OPERMODE_EPM

W

Y

R/W

CAN Bus Parameter: Boot-up Mode: 0 - 2
(Operational State Control)
0 - enters into pre-operational state
1 - enters into operational state
2 - pseudo NMT: sends NMT Start Node
command after delay (set by variable 237)

237

VAR_CAN_OPERDELAY_EPM

W

Y

R/W

CAN Bus Parameter: pseudo NMT mode
delay time in seconds (refer to variable 236)

sec

238

VAR_CAN_ENABLE_EPM

W

Y

R/W

CAN Bus Parameter: Mode Control: 0, 1, 2
0 - Disable CAN interface
1 - Enable CAN interface in DS301 mode

Concurrent user’s program execution
possible

2 - Enable CAN interface in DS402 mode

Concurrent user’s program execution
possible

3 - Enable DeviceNet
4 - Enable PROFIBUS DP

239

VAR_HOME_ACCEL

F

Y

Homing Mode: ACCEL rate: 0 - 10000000.0

UU/sec

2

240

VAR_HOME_OFFSET

F

Y

R/W

Homing Mode: Home Position Offset
Range: -32767 to +32767

UU

241

VAR_HOME_OFFSET_PULSES

W

Y

R/W

Homing Mode: Home Position Offset in
encoder counts
Range: +/- 2,147,418,112

EC

242

VAR_HOME_FAST_VEL

F

Y

R/W

Homing Mode: Fast Velocity
Range: -10,000 to +10,000

UU/sec

243

VAR_HOME_SLOW_VEL

F

Y

R/W

Homing Mode: Slow Velocity
Range: -10,000 to +10,000

UU/sec

244

VAR_HOME_METHOD

W

Y

R/W

Homing Mode: Homing Method
Range: 1 - 35

245

VAR_START_HOMING

Short Name: HOME

W

N

W

Homing Mode: Start Homing: 0, 1
0 - No action
1 - Start Homing

246

VAR_HOME_SWITCH_INPUT

W

Y

R/W

Homing Mode: Switch Input Assignment:
Range: 0 - 11
0 - 3: A1 - A4
4 - 7: B1 - B4
8 - 11: C1 - C4
Warning: If using A1, A2 or C3 refer to the
homing section. Do not use input A3 as
homing switch.

Advertising