Reference – Lenze E94P PositionServo with MVOB User Manual

Page 114

Advertising
background image

112

L

PM94H201B_13xxxxxx_EN

Reference

Index Name

Type Format EPM Access Description

Units

171

VAR_NV31

Short Name: NV31

F

N

R/W User defined Network variable.

Variable can be shared across Ethernet network.

172

VAR_SERIAL_ADDRESS

W

Y

R/W RS485 drive ID. Range: 0 - 254

173

VAR_MODBUS_BAUDRATE

W

Y

R/W

Baud rate for ModBus operations:
2 - 9600
3 - 19200
4 - 38400
5 - 57600
6 - 115200

174

VAR_MODBUS_DELAY

W

Y

R/W

ModBus reply delay in mS
Range: 0 - 1000

mS

175

VAR_RS485_CONFIG

W

Y

R/W

Rs485 configuration:
0 - normal IP over PPP
1 - ModBus

176

VAR_PPP_BAUDRATE

NOTE: Does NOT apply to

MVOB.

W

Y

R/W

RS232/485 (normal mode) baud rate:
2 - 9600
3 - 19200
4 - 38400
5 - 57600
6 - 115200

177

VAR_MOVEPS

mtn

F

N

W

Same as variable #92 but using S-curve
acceleration/deceleration

178

VAR_MOVEDS

mtn

F

N

W

Same as variable #93 but using S-curve
acceleration/deceleration

179

VAR_MDVS_VELOCITY

mtn

N

W

Velocity for MDV move using S-curve accel/
deceleration. Writing to this variable executes
MDV move with Distance value last written
to variable #94 (unless motion is suspended
by #91).

UU

180

VAR_MAXVEL

Short Name: MAXV

F

N

R/W Max velocity for motion profile

UU/S

181

VAR_ACCEL

Short Name: ACCEL

F

N

R/W Accel value for indexing

UU/S

2

182

VAR_DECEL

Short Name: DECEL

F

N

R/W Decel value for indexing

UU/S

2

183

VAR_QDECEL

Short Name: QDECEL

F

N

R/W Quick decel value

UU/S

2

184

VAR_INPOSLIM

Short Name: INPOSLIM

W

N

R/W Sets window for “In Position” Limits

UU

185

VAR_VEL

Short Name: VEL

F

N

R/W Velocity reference for “Profiled” velocity

UU/S

186

VAR_UNITS

Short Name: UNITS

F

Y

R/W User units

187

VAR_MECOUNTER

Short Name: MECOUNTER

W

N

R/W A/B inputs reference counter value

Count

188

VAR_PHCUR

Short Name: PHCUR

F

N

R

Phase current

A

189

VAR_POS_PULSES

Short Name: TPOS_PLS

W

N

R/W Target position in encoder pulses

EC

190

VAR_APOS_PULSES

Short Name: APOS_PLS

W

N

R/W Actual position in encoder pulses

EC

191

VAR_POSERROR_PULSES

Short Name: PERROR_PLS

W

N

R

Position error in encoder pulses

EC

Advertising