Scope of supply

Description

Use

Amount

0

9300 vector frequency inverter ˘ master

1

1

9300 vector frequency inverter ˘ slave

1

2

Mounting Instructions

1

3

Mounting rail

4

^ 78

4

Hexagon socket screw M8 × 25 mm

Fastening of the controller with the mounting rail

3 on the mounting plate

24

5

Spring washer M8

24

6

DC busbar for +U

G

+U

G

connection between master and slave

1

^ 82

7

DC busbar for −U

G

−U

G

connection between master and slave

1

8

Distance sleeve M8

Fastening of the DC busbars

6 7 in the master

and slave

6

9

Hexagon socket screw M8 × 45 mm

6

:

Plain washer M8

6

;

EMC shield sheet for shielded control cables

1

^ 95

<

Recessed head screw M4 × 12 mm

Fastening of EMC shield sheet

5

2

=

Shield clip

Connection of the cable shields to the shield sheet

3

>

4−pole terminal strip

Safety relay K

SR

at X11

1

^ 97

?

7−pole terminal strip

Digital inputs and outputs at X5

2

^ 95

@

4−pole terminal strip

Analog inputs and outputs at X6

2

^ 95

.

3−pole terminal strip

System bus (CAN) at X4

1

^ 103

/

Protective cover

Protection for unused Sub−D sockets

4

Connections and interfaces

Description

Function

‚

Power terminals

Controller mains connection for 400 V

^ 86

Controller mains connection for 500 V

^ 87

ƒ

Power terminals

Connection to the DC bus

^ 88

„

Power terminals

Motor connection

^ 91

x1

Control interface

Plug−in station, e.g. for keypad

X3

Jumper

Setting of analog input signal at X6/1, X6/2

^ 102

X4

Control terminals

System bus (CAN)

^ 103

X5

Control terminals

Digital inputs and outputs

^ 95

X6

Control terminals

Analog inputs and outputs

^ 95

X8

Sub−D socket

Incremental encoder input

^ 105

X9

Sub−D socket

Incremental encoder input

^ 106

Digital frequency input

^ 107

X10 Sub−D socket

Digital frequency output

^ 107

X11 Control terminals

Safety relay K

SR

^ 97

Status displays

Position

LED red

LED green

Operating status



Off

On

Controller is enabled

On

On

Mains is switched on and automatic start is inhibited

Off

Blinking slowly

Controller is inhibited

Off

On

Motor data identification is active

Blinking quickly

Off

Undervoltage or overvoltage

Blinking slowly

Off

Active fault

0Fig. 0Tab. 0