Mechanical installation

Drilling the holes into the mounting plate

4

l

77

EDKVF9383 DE/EN/FR 4.0

4

Mechanical installation

I

Tip!

ƒ

Lenze recommends to install an air lock. The air lock serves to dissipate the
heated cooling air directly from the control cabinet.
– Order no. E93ZWL2

ƒ

A drilling jig for marking the bore holes is available as dxf−file in the
Internet in the "Download" area under www.Lenze.de.

4.1

Drilling the holes into the mounting plate

Assembly space

Minimum clearance

Left/right of other controllers

30 mm

Left/right of a non−heat−conducting wall

100 mm

Top/bottom

200 mm

Comply with the clearances given to ensure a sufficient cooling of the controller. When
using an air lock, different clearances apply (see Mounting Instructions for the air lock).

a

a1

a1

a1

a1

a3

a3

a2

a2

a2

a2

d

b

93vec079

Fig.4−1

Bore holes in the mounting plate for fixing the controller

a

a1

a2

a3

b

d

550 mm

450 mm

340 mm

225 mm

1005 mm

9 mm (24x)

1. Mark the bore holes on the mounting plate according to the figure.

2. Drill the holes into the mounting plate.