Electrical installation

Motor connection
Fan connection

5

l

92

EDKVF9383 DE/EN/FR 4.0

Motor connection

0

1

BR2

BR2

BR1

BR1

PE

PE

U

U

V

V

W

W

40 mm

40 mm

PE

15-20 Nm

M6

133-176 lb-in

PE

15-20 Nm

M6

133-176 lb-in

U, V, W

25-30 Nm

M8

221-264 lb-in

U, V, W

25-30 Nm

M8

221-264 lb-in

2

2

3

3

max.

300 mm

max.

300 mm

9300VEC036

Fig. 5−12

Motor connection example

BR1, BR2

Brake resistor can only be operated with the variants V060, V110, V270 and V300
For connection see System Manual of 9300 vector

0

Master terminals

1

Slave terminals

2

Connect the motor cable shield with a surface as large as possible to the control
cabinet mounting plate by using the clamps.

3

Conductive surface

Ensure to have the poles right!
Do not exceed the maximum motor cable length!

Cable cross−sections for the motor connection

Type

Installation to EN 60204−1

U, V, W [mm

2

]

PE [mm

2

]

Master

Slave

Master

Slave

EVF9381−EV
EVF9381−EVxxxx

150

2 Ч 50

1)

150

2 Ч 50

1)

95

95

EVF9382−EV
EVF9382−EVxxxx

150

2 Ч 50

1)

150

2 Ч 50

1)

95

95

EVF9383−EV
EVF9383−EVxxxx

240

2 Ч 95

1)

240

2 Ч 95

1)

150

150

1)

Multiple conductor; both conductors must have the same cross−section

Observe the national and regional legislation