1 wiring of motor temperature monitoring, Wiring of motor temperature monitoring, Electrical installation – Lenze EVF9383 User Manual

Page 93: Connection to incremental encoder input (x8)

Advertising
background image

Electrical installation

Motor connection

Wiring of motor temperature monitoring

5

l

93

EDKVF9383 DE/EN/FR 4.0

5.5.1

Wiring of motor temperature monitoring

The drive controller features 2 connections for motor temperature monitoring:

ƒ

Terminals T1, T2 for connecting a PTC thermistor or thermal contact (NC contact).

ƒ

Pin X8/5 and X8/8 of the incremental encoder input (X8) for connecting a KTY
thermal sensor.

Incremental encoder input (X8)

Terminals T1, T2

Connectable thermal
sensor

Linear thermal sensor (KTY)

l

PTC thermistor
– PTC thermistor with defined

operating temperature (to
DIN 44081 and DIN 44082)

l

Thermal contact (NC contact)
– Temperature switch as NC contact

Tripping point

l

Warning: Adjustable

l

Error (TRIP): Fixed at 150 °C

l

Fixed, (depending on the PTC/thermal
contact)

l

PTC: R

J

>

1600

W

l

Configurable as warning or error
(TRIP)

Notes

l

Monitoring is not active in the Lenze
setting.

l

The KTY is monitored with regard to
interruption and short circuit.

l

Monitoring is not active in the Lenze
setting.

l

If you do not use a Lenze motor, we
recommend a PTC thermistor up to
150°C.

Connection to incremental encoder input (X8)

)

Note!

Lenze system cables for motor feedback include additional cores for
temperature feedback. The cables are designed for wiring according to EMC.

B

V

CC5 _ E

GND

Z

+KTY

-KTY

1
2

3
4
5
6
7
8
9

A

X8

A

B

Z

KTY

9300VEC068

Fig. 5−13

Connection to incremental encoder input (X8)

X8/5, X8/8

Connection of KTY thermal sensor

Advertising
This manual is related to the following products: