Lenze MCH Series User Manual
Page 18
![background image](/manuals/566125/18/background.png)
14
13435744_EDBMH01_v13
MH400 SERIES RATINGS
MODEL
INPUT
OUTPUT
(400/480 Vac, 50 - 60 Hz)
(0 - 400/460 Vac)
MODEL
NUMBER
(NOTE 1)
FOR MOTORS
INPUT
PHASE
NOMINAL
NOMINAL
RATED
CURRENT
POWER
CURRENT
POWER
HP
kW
(AMPS)
(KVA)
(AMPS)
(KVA)
MH410
1
0.75
3
2.8 / 2.4
2.0
2.3 / 2.0
1.6
MH420
2
1.5
3
4.7 / 4.1
3.4
3.9 / 3.4
2.7
MH430
3
2.2
3
6.6 / 5.7
4.7
5.5 / 4.8
3.8
MH450
5
3.7
3
10.2 / 8.9
7.3
8.7 / 7.6
6.1
MH475
7.5
5.5
3
14.7 / 12.8
10.6
12.6 / 11.0
8.8
MH4100
10
7.5
3
18.3 / 15.9
13.2
16.0 / 14.0
11.2
MH4150
15
11
3
28 / 24
19.8
24 / 21
16.7
MH4200
20
15
3
36 / 31
25.3
31 / 27
21.5
MH4250
25
18.5
3
44 / 38
31.9
39 / 34
27.1
MH4300
30
22
3
52 / 45
37.6
46 / 40
31.9
MH4400
40
30
3
68 / 59
49.0
60 / 52
41.4
MH4500
50
37.5
3
85 / 74
61.5
75 / 65
51.8
MH4600
60
45
3
100 / 87
72.3
88 / 77
61.3
MH4750
75
55
3
91 / 91
75.5
96 / 96
76.5
MH41000
100
75
3
116 / 116
96.4
124 / 124
98.8
MH41250
125
90
3
146 / 146
121.4
156 / 156
124.3
MH41500
150
110
3
168 / 168
139.7
180 / 180
143.4
MH42000
200
150
3
225 / 225
187.1
240 / 240
191.2
MH42500
250
185
3
281 / 281
233.6
300 / 300
240.6
NOTE 1: Refer to Section 3.0 for model number breakdown.
NOTE 2: Refer to Section 8.0 for recommended fuse type.