MCH CONTROL WIRING DIAGRAMS

The following wiring diagrams apply to standard MCH drives. Refer to Appendix A for

control wiring for the Bypass option, or Appendix B for control wiring for the Option Box.

15.1

MCH TERMINAL STRIP

Shown below is the terminal strip on the main control board, along with a brief description

of the function of each terminal.

RUN / ST

OP

CIR
CUIT C

OMMON

0-10

VDC SPEED REFERENCE INPUT

10
VDC SUPPL

Y FOR SPEED PO

T

0-10 OR 2-10

VDC OUTPUT

: FREQUENC

Y

0-10 OR 2-10

VDC OUTPUT

: L

O

AD

CIR
CUIT C

OMMON

AUT

O MODE SELEC

T

TB

-13A FUNC

TION SELEC

T

TB

-13B FUNC

TION SELEC

T

TB

-13C FUNC

TION SELEC

T

TB

-13D FUNC

TION SELEC

T

OPEN-

COLLEC

TOR OUTPUT

OPEN-

COLLEC

TOR OUTPUT

RS

-485 SERIAL

COMMUNIC

ATIONS

CIR
CUIT C

OMMON

4-20 mA SPEED REFERENCE INPUT

1 2 5A 5B 6 10A

12A

RXA TXB

10B 2

13A 13B 13C 13D 14 15 2

16 17 18

FORM C

RELAY

The TB-2 terminals are internally tied together

NOTE:

The function of terminals TB-10A, TB-10B, TB-13A, TB-13B, TB-13C, TB-

13D, TB-14, TB-15, TB-16 and TB-18 are dependent on the programming

of certain parameters. In most cases, the name of the parameter matches

the number of the terminal, allowing quick and easy programming of the

terminals to suit the application. The exception is TB-16 and TB-18, which

are governed by Parameter 54 - RELAY.

A complete description of operating the drive in the AUTO mode can be found in Section

14.2. The following diagrams provide a quick reference to wire the drive for the most

common configurations.