Configuration – Lenze 8200 series User Manual

Page 53

Advertising
background image

Configuration

UOMu_^MVMO

7-5

Code

IMPORTANT

Possible settings

Name

Code

IMPORTANT

Info

Selection

Lenze

Name

C009* Device address

1

1

{1}

99

Only for

LECOM

applications

C010 Minimum field

frequency

0.0

0.0

{0.1Hz}

480.0

C011 Maximum field

frequency

820X 50.0 30.0

{0.1Hz}

480.0

821X 50.0 7.5

{0.1Hz}

480.0

30.0

{0.1Hz}

480.0

(Software 2x)
(Software 1x)

822X/824X 50.0 7.5

{0.1Hz}

480.0

C012 Acceleration

time

5.0

0.0

{0.1s}

999.0

C013 Deceleration

time

5.0

0.0

{0.1s}

999.0

C014

¿

Operating mode

820X

-0-

-0- Linear characteristic V~f

d

with auto

boost

-1- Square characteristic V~f

d

2

with auto

boost

-2- Linear characteristic V~f

d

with constant

V

min

boost

-3- Square characteristic V~f

d

2

with

constant V

min

boost

821X/822X

/ 824X

-4-

-4- Motor-current control

C015 V/f-rated

frequency

820X 50.0 30.0

{0.1Hz}

960.0

821X 50.0 7.5

{0.1Hz}

960.0

30.0

{0.1Hz}

960.0

(Software 2x)
(Software 1x)

822X/824X 50.0 7.5

{0.1Hz}

960.0