Troubleshooting and fault elimination – Lenze 8200 series User Manual

Page 64

Advertising
background image

Troubleshooting and fault elimination

8-6

UOMu_^MVMO

Function

You can select whether the active fault is to be reset automatically or manually.

Auto-Trip reset does not reset all faults automatically.

Activation

C170 = -0-:
D

Manual TRIP-reset

D

STP key

D

LOW signal at terminal 28

C170 = -1-:
Auto-Trip reset resets the following fault messages after the time set under C171:

- OC3 (overload during acceleration)
- OC4 (overload during deceleration)
- OC5 (overload)
- OC6 (I

¡

t switch-off)

- OH (overtemperature)
- OUE (overvoltage in DC bus)

Important

Mains switching always resets TRIP.
With more than 8 auto-trip resets within 10 minutes, the controller sets TRIP and

indicates rST (numerator exceeded).