MK-101 Pro24 JCS SETUP

WATER PUMP SETUP FOR OPERATION

External Water Source

Re-circulation

The Water Pump can be setup for operation in two ways, External Water Source or Re-circulation.

This is the preferred method of cooling.

NOTE:

If using a dry blade for operation, DO NOT connect the water pump.

(A)

Remove the Drain Plug. Place

empty container under hole for

water drainage.

(B)

Place the Water Pump in an

external container and fill until

water completely covers the

Water Pump suction.

(B)

Place Water Pump in Water Pan.

(C)

Place Water Pump Clamp as

shown.

(D)

Secure Clamp with wingscrews

and nuts. Fill the Water Basin

until water completely covers the

Water Pump suction.

When using the re-circulation method, the water should be changed often for

longer pump life.

(A)

Ensure the Drain Plug is

installed in the Water Basin.

NOTE: