MK Diamond MK-101Pro24 JCS User Manual

Page 39

Advertising
background image

39

MK-101 Pro24 JCS TROUBLESHOOTING

Cooling Flow

(A)

Verify the cooling flow

Adjusting Clamp is open. If flow

exists, go to Step A.

(B)

Remove the Cooling Transfer

Tube from the Blade Guard

inlet. Go to Step C.

(C)

Place Pump into a bucket of

water and check flow. If flow

exists, go to Step D.

(D)

Remove the Cooling Transfer

Tube and check for flow. If flow

exists, refer to water manual.

(E)

Remove the Blade Guard

Intake Fitting. Go to Step J.

(F)

Remove the Cooling Channel

cover screws.

(G)

Rod the Cooling Channels

and then recheck flow.

“Rodding” cooling channels is performed by inserting

a small wire rod through the cooling inlet on top of the

Blade Guard and directing the rod out through each of

the cooling flow tubes located on the underside o the

Blade Guard. The cooling channels should be “rodded”

until all ports are free of foreign debris.

NOTE: