SPL/RTA - Real Time Analyzer RTA

The Acoustilyzer sound level meter features 1/3

rd

or full octave band test

results using class 0 filters. The SPL, MAX / MIN and Leq values are

displayed per band.

Stored spectra may be averaged by using the available mathematical

functions. The MAX-MIN display is particularly helpful for characterizations

of listening areas.

Input Range

indicator arrows

Audio

Spectrum

Set

Menu

Pause

Reset

Cursor

Readout

X-Axis with manual

range selection

Y-Axis

The audio spectrum is displayed without interrupting any ongoing sound

level measurements, so e.g. changing from

to

screen will not

interrupt the ongoing sound level measurements.

Input Filter

The SPL/RTA input filter for the broad band values (

) and the RTA (

)

may be selected independently - so e.g. a FLAT RTA is available while the

broad band values are acquired using an A weighted filter. Please note that

only various filter combinations are possible.

Note: Changing filter settings re-starts the ongoing measurement.