51

How to measure

Note: Please de-activate any shock

protection of the CD-player since

this might cause incorrect test

results!

Test preparations
• Switch on the acoustical delay time

measurement signal, available on the

AL1 Test CD.

• Connect the electrical signal, e.g. from

the CD player, to the AL1 RCA or XLR

input.

• Wait until the Acoustilyzer synchronizes

to the incoming delay time test chirp and

the synchronization time bar fills up to

100%.

The delay time measurement is conducted

between the synchronized electrical input

signal and the built-in microphone of the

Acoustilyzer.

Measure Reference Speaker
• Select a speaker as reference speaker,

called speaker A, e.g. the first speaker in

the delay line.

• Position yourself in the sound field of

the next speaker under test, e.g. called

speaker B, to measure the delay time

compared to the reference speaker A.

Note: Do not position the Acoustilyzer

too close to reflecting surfaces,

such as walls or floors. The

reflections may interfere with

accurate measurements.