STI-PA - Speech Transmission Index for Public Address Systems

A rising awareness of security issues from unintelligible speech, new

technological means and the shortcomings of RASTI triggered the speaker

manufacturer Bose and the research institute TNO to develop a new method

for speech intelligibility measurements of PA installations. The result of

these efforts is STI-PA, which allows quick and accurate tests with portable

instruments.

Like RASTI, STI-PA applies a simplified procedure to calculate the MTF.

But STI-PA determines the MTF by analyzing all seven frequency bands,

whereby each band is modulated with two frequencies.

Supposing that no severe impulsive background noise is present and

that no massive non-linear distortions occur, STI-PA provides results as

accurate as STI. If however impulsive background noise is present during

the normal system operation hours, it is usually possible to mitigate the

effects by also acquiring a measurement at a more favorable time e.g.

under slightly different conditions in the area, or during the night time - and

to calculate an unbiased overall measurement by using the results of both

test cycles.

NTi Audio STI-PA measurement table:

Portable STI-PA analyzers, e.g. NTi Audio’s Acoustilyzer, are able to

evaluate speech intelligibility within 15 seconds per position and are thus

well suited for wide-area measurements and high productivity.