STI, RASTI or STI-PA

STI, RASTI or STI-PA are the most established methods for measuring

speech intelligibility. All three of them basically apply the same principle,

whereby RASTI and STI-PA are a simplified version of STI. This article

explains the principles behind these methods.

Speech Model:

First of all, measuring the speech intelligibility requires a model for speech

signals. For instance, speech may be described as superposition of various

phoneme frequencies that are modulated (i.e. of which the amplitude is

varied).

Frequency Spectrum:

The frequency analysis of a male voice

over a certain period results in a typical

characteristic as shown in Figure 1.

Fig. 1: Averaged octave

band spectrum of a male

speaker.

Time Modulations:

Within each frequency band, the signal

level varies, i.e. it is “modulated” by the

speaker. Figure 2 shows the envelope of a

speech signal in the 250 Hz band, whereby

the shape of the envelope is given by the

speech contents.

By analyzing the spectra of envelope

sequences it can be shown that a speaker

modulates the individual frequency bands in

the range from 0.2 to 12.5 Hz.

Fig. 2: Envelope of a speech

signal (250 Hz band).

Fig. 3: frequency spectrum

of the envelope of a speech

signal (250 Hz band).