• Start the STI-PA test signal.
• Set the acoustical sound pressure level

of the PA system according the typical

emergency condition requirements, e.g.

85 dBAS.

• Press START on the AL1 menu to initiate

the measurement. Ensure that there is

no speaking or additional noise near the

measurement microphone during the

measurement.

A STI-PA measurement takes 15 seconds.

The elapsed test time is visible in the upper

measurement progress bar.

The test result tendency is shown on the

STI-PA bargraph below, marked with BAD,

PR (poor), FR (fair), GD (good) and EXLT

(excellent).

After the 15 seconds test cycle time the

Measurement Status Indication switches to

FINISHED and the final STI-PA test result

is displayed.

On the bargraph below the quality of the

speech intelligibility test result is displayed

as

• BAD 0.00 - 0.30 STI

• PR (poor) 0.30 - 0.45 STI

• FR (fair) 0.45 - 0.60 STI

• GD (good) 0.60 - 0.75 STI

• EXLT (excellent) 0.75 - 1.00 STI