Change

[m][°C] ↔ [feet][°F]

• Enable the test signal at the reference

speaker A. Switch off all other

speakers.

• The delay time of the acoustic signal

with reference to the electrical input

signal is displayed in milliseconds. The

distance result in meter/feet is displayed

for easy verification of the test results.

The readings are based on 330 m/s

sound speed at 0°C / 32°F.

• Set the actual environment temperature,

so the distance is displayed correctly.

Store reference
• Select STORE to memorize this test

result as reference record for further

delay time measurements.

• The stored reference delay time is

shown in the delay time memory field.

Measure Propagation Time at Speaker B
• Enable the test signal at the speaker B.

Switch off all other speakers.

• The acoustical delay time of speaker

B with reference to the electrical input

signal is displayed as big test result.

Automatic Time Difference Calculation
• The delay time difference is automatically

calculated and shown in the upper small

STO-ACT (stored - actual) field.

The automatic difference calculation

simplifies the verification of delay line

arrangements, e.g. used in larger halls

or auditoriums.