Technical specification – NTi Audio Acoustilyzer AL1 User Manual

Page 86

Advertising
background image

86

87

8. Technical Specification

Measurements

• Sound Pressure Level

• Real Time Analyzer

• Zoom FFT

• Reverberation Time

• Delay Time

• Level RMS, Distortion THD+N

• Frequency

• Polarity Test

• Speech Intelligibility STI-PA (optional)

Sound Pressure Level

• SPL, Leq, LCpeak, Lmin, Lmax in accordance with IEC 61672

• Timer for single and repeated measurements

• Dynamic range (using MiniSPL): 30 - 130 dBSPL

A

• Filters: Flat, A, C, X-Curve

-1

, RLB (Broadcast Loudness)

• Logging of SPL/RTA results into AL1 memory

• Wideband and RTA values simultaneously available

Real Time Analyzer

• 1/3 or full octave band resolution, class 0 filters

• SPL, Leq and Max-Min display per band

Reverberation Time

• 1/1 Octave band resolution, 63 Hz - 8 kHz,

based on T20 results, according to ISO3382

• 1/3 Octave band resolution with post-processing

• Automatic averaging with individual result readout and storage

• Source signal: Gated pink noise (from Test-CD or Minirator)

Zoom FFT

• Real-time Zoom FFT with 50% overlapping, 93 Bins

• Frequency Range: 10 Hz - 20 kHz

• Resolution: 187.5 Hz to 0.73 Hz

Delay Time

• Propagation delay between electrical and acoustic signal

input using built-in mic. Resolution < 0.1ms, max time: 1 s

• Dedicated test signal: NTi Audio chirp (from Test-CD or Minirator)

Advertising