87

Polarity Test

Positive / Negative detection through internal microphone or

XLR RCA connector

.

Checks polarity of midrange-speakers, woofers, sub-woofers

and cables

.

Down to 10 dB S/N ratio of input signal

.

• Testsignal: NTi Audio Polarity Signal (AL1 Test CD or Minirator)

Electrical

• Level RMS, THD+N, Frequency, Polarity

• Filters: Flat, A-weighting, C-weighting, Highpass 400 Hz,

Highpass 19 kHz

STI-PA (Option)

• Single value STI and CIS test result. Modulation indices

and individual band level results accessible. Error indicator.

• Fulfills the IEC 60268-16 release 2003 standard

(including amplitude weighting)

• TNO verified algorithm

Frequency

• Range

10 Hz to 20 kHz

• Resolution

4 digits

• Accuracy

< ± 0.1 %

Level

• Units

dBu, dBV, V

RMS

• Resolution

3 digits (dB-scale) or 4 digits (V-scale)

• Accuracy

± 0.5 % @ 1 kHz

• Bandwidth

20 Hz to 20 kHz

• Flatness

± 0.1 dB

THD+N (Total Harmonic Distortion + Noise)

• Bandwidth

10 Hz to 20 kHz

• Resolution

3 digits (dB-scale) or 4 digits (%-scale)

• Residual

balanced < -85 dB @ -10 dBu to +20 dBu

THD+N

unbalanced < -74 dB @ 0 dBu to +14 dBu

PC Interface

• Internal device memory for up to 580 records

• USB interface to MiniLINK PC software

• Online data logging from Acoustilyzer directly to PC