C. rt60 test result readout – NTi Audio Acoustilyzer AL1 User Manual

Page 40

Advertising
background image

40

41

Test result readout

The detailed RT60 test results in

x.xx seconds are listed in the RT60 test

result screen. Select the detailed test result

readout screen by
• Using the screen menu
• Alternatively press the ESC and the left

or right arrow key simultaneously.

Note: During the ongoing RT60

measurement the memory menu

is not available.

c. RT60 Test Result Readout

Test Result

in seconds

Correlation Factor in %

or Measurement Uncertainty

Relative Test

Result, displayed as

bargraph

Test Result

Selection

Number of

continuously

taken test

results

Delete selected

Test Result

Start

Pause

Octave

bands scroll

63Hz - 8kHz

Test Result Selection: The RT60 measurement function enables

consecutive reverberation time measurements within one test

sequence. Automatically an averaged test result of all measurements

is calculated.

Advertising