Rockwell Automation Publication 842E-UM001A-EN-P May 2012

19

Installation

Chapter 4

9.

Remove the screw cover on the back of the encoder and press the preset
push button to change the preset value to the current shaft position value.
(The factory preset value is zero.)

10.

Replace the screw cover.

Mechanical specifications

Electrical

Electrical wiring instructions

Three electrical connections are located on the back of the housing.

A 4-pin M12 connector is used for the power supply connection.

Two 4-pin M12 connectors are used for the ethernet connection. The Link 1
connection is used for star networks. For ring networks, use both the Link 1 and
Link 2 connectors. In a linear network, use Link 1, Link 2, or both connectors.

Face mount flange

10 x 19 mm

Servo flange

6 x 10 mm

Blind hollow shaft

8, 19, 12, 15 mm and 1/4, 1/2, 3/8, 5/8 in.

ATTENTION

Switch off the power supply. The machine/system could unintentionally start
while you are connecting the devices.

Ensure that the entire machine/system is disconnected during the electrical
installation.

ATTENTION

Commissioning requires a thorough check by authorized personnel!

Before you operate a system equipped with the 842E EtherNet/IP absolute
encoder, make sure that the system is first checked and released by authorized
personnel.

Please read more in Chapter 1, Safety.

Net

Mod

Link 1

Link 2

Encoder

Network
Address

Switches

x1

x10

x100

Reset

Button

Power connection

Link 1 connection

Network address

switches

Link 2 connection

Preset push button