16

Position
error

Single-turn position error (error in the
sensor)

0

1

YES

A

2

17

Position
error

Multi-turn position error
(synchronization MA single)

0

1

YES

A

18

Position
error

Multi-turn position error
(synchronization quad single)

0

1

YES

A

19

Position
error

Multi-turn position error (internal
interface)

0

1

YES

A

20

Position
error

Multi-turn position error (FRAM)

Always
0

NO

A

21…23 Reserved

Reserved

Always
0

NO

24

Position or
memory
error

Memory error (EEPROM checksum)

0

1

YES

A

3

25

Memory
error

Memory error (EEPROM IRQ)

0

1

YES

A

26

Startup error Error on start-up

0

1

YES

A

27

Diagnostic
error

Error during self-test

0

1

YES

A

28…29 Reserved

Reserved

30

Slave sign of
life

LifeSign; active if attribute 13 is set

0

1

YES

31

Reserved

Reserved

Always
0

NO

Fault