Configuring the 842 E encoder using RSLogix 5000

Module definition

The user should not have to make changes to the default values. If necessary,
follow the steps below to change series, revision, electronic keying, connection,
and/or input data.

1.

On the General tab, click the Change button. The module definition
window opens.

2.

Click the arrows at the right of each box to access drop-down menus.

The connection drop-down menu allows you to select either a Data or
Listen Only

connection (see definitions, below).

The Input data drop-down menu allows you to select position, position-
status, or position-velocity (see “RSLogix 5000 controller tags” on page 41
for more information).

3.

Click OK to accept the changes (or Cancel to retain the original settings).
See the definitions below. Click Help for more information.

Data:

This type of connection is used to read data from the encoder without

controlling the outputs. This connection is not dependent on any other
connection.

Listen Only:

This type of connection is dependent on another connection to

exist. If that connection is closed, the listen-only connection will be closed as
well.