7 - diagnostics and troubleshooting, Status indicators, Chapter 7 – Rockwell Automation 842E EtherNet/IP Absolute Encoder User Manual User Manual

Page 51: Diagnostics and troubleshooting, Chapter

Advertising
background image

Rockwell Automation Publication 842E-UM001A-EN-P May 2012

43

Chapter

7

Diagnostics and troubleshooting

This chapter describes the diagnostic process to correct and clear fault conditions
on the 842E encoder.

Status indicators

The Mod LED shows the device status, the Net LED shows the status of the CIP
connection, and the Encoder LED shows the status of the internal measuring
device in the 842E EtherNet/IP encoder.

Five LED indicators provide status information on the back of the encoder. The
figure below shows their location and the tables below describe their status.

Read the LEDs according to the following tables.

ATTENTION

Cease operation if the cause of the malfunction has not been identified!

Stop the machine if you cannot clearly identify the error and/or if you cannot
safely rectify the malfunction.

LED Net

Description

OFF

No power
or
No IP address

Green flashing

No connection
The device has an IP address but no CIP connection.

Green

The device has an IP address and a CIP connection.

Net

Mod

Link 1

Screw cover

Encoder

Link 2

Advertising