Functions 3-3

Key Protect Level (

kypt

)

When the key-protect switch in set to ON, it is possible to prevent setting
errors by prohibiting the use of certain operation keys by specifying the key
protect level (KP-1 to KP-7). The key protect indicator is lit while the
key-protect switch is set to ON. Confirm the ON/OFF status of the
key-protect switch after the 700-HX is mounted to the panel.

Level

Meaning

KP-1
(default
setting)

Prohibits changing the mode to timer/repeat
cycle selection mode or function setting
mode. The 700-HX can only be used in run
mode.

KP-2

Prohibits changing the mode to timer/repeat
cycle selection mode or function setting
mode. The 700-HX can only be used in run
mode. Also prohibits use of the reset key.

KP-3

Prohibits changing the mode to timer/repeat
cycle selection mode or function setting
mode. The 700-HX can only be used in run
mode. Also prohibits use of the up and down
keys.

KP-4

Prohibits changing the mode to timer/repeat
cycle selection mode or function setting
mode. The 700-HX can only be used in run
mode. Also prohibits use of the reset, up and
down keys.

KP-5

Prohibits changing the mode to timer/repeat
cycle selection mode or function setting
mode. The 700-HX can only be used in run
mode. Also prohibits use of any operation
keys.

KP-6

Prohibits changing the mode to timer/repeat
cycle selection mode or function setting
mode. The 700-HX can only be used in run
mode. Also prohibits use of the mode key.

KP-7

Prohibits changing the mode to timer/repeat
cycle selection mode or function setting
mode. The 700-HX can only be used in run
mode. Also prohibits use of mode and reset
keys.

ON

OFF

Key protect indicator

Note: Factory-set to OFF

(See note)